| Hardware Specifications | |
|---|---|
| CPU | Texas Instruments Sitara ARM Cortex A8 AM3352 1000MHz |
| Flash | 32 MB NOR Flash (customizable upon request up to 64 MB) |
| RAM | 256 MB DDR3 (customizable upon request up to 1 GB) |
| EEPROM | 24LC64 |
| Watchdog | ADM706 |
| Real Time Clock (RTC) | Yes - with external chip |
| Buzzer | Yes |
| Console port | Yes - RJ45 Serial Console |
| Reset Button | Yes |
| Network Interface | |
|---|---|
| Standards | IEEE 802.3 for 10BaseT IEEE 802.3u for 100BaseT(X) and 100BaseF(X) |
| Ethernet Ports | 6x 10/100 BASE-T(X) RJ45 or 6x 100 BASE-F(X) SFP Slots (SFP version) |
| Ethernet Switch | Embedded 8-Ports Fast-Ethernet Switch (configurable). Each port can work as single Subnet or as Switch |
| Serial Interface | |
|---|---|
| Connector | DB version: D-Sub9 (DB9) connector TB and SiS version: 5-Pin Terminal Block (5.08mm) |
| Ports | SE5908A: 8-ports (RS-232 (supports only 5-pin mode)/RS-422/RS-485) SE5916A: 16-ports (RS-232 (supports only 5-pin mode)/RS-422/RS-485) |
| Serial Console | 1x Serial Console port (RJ45) |
| Serial Port Isolation | 3 kV (SiS version only) |
| Pull-high / Pull-low /Term. resistors | Software Selectable |
| Baud Rate | 50 ~ 921,600bps |
| Data Bits | 5, 6, 7, 8 |
| Stop Bits | 1, 2 |
| Flow Control | None, Xon/Xoff, RTS/CTS (RS-232 only) |
| Other interfaces | |
|---|---|
| USB ports | No |
| LCM Matrix | Programmable LCM Matrix with 5-buttons |
| SD Card | SD card slot (internal) |
| Relay Output | 1x 1A@30VDC (Normal open) |
| Software | |
|---|---|
| Bootloader | U-boot 2014.07 |
| Linux kernel | Linux 3.14.26 |
| Linux toolchain | Linux 32 bits toolchain gcc (C/C++ PC cross compiler), glibc |
| Linux sample code | RS232, RS485, RTC, watchdog, LED, Buzzer, Button, network socket |
| Power | |
|---|---|
| Rated Aupply Voltage | Redundant 24-48 VDC or Redundant 100-240 VAC/ 100-370 VDC (HV Series) |
| Input Voltage Range | Redundant 19.2-52.8 VDC or Redundant 85-264 VAC/ 100-370 VDC (HV Series) |
| Input Current | 0.73 A @ 24 VDC 0.35 A @ 100 VAC 0.20 A @ 100 VDC |
| Power Consumption | Approximately 20 W |
| Connector | 10-Pin Terminal Block |
| Power Redundancy | Yes |
| Reverse Polarity Protection | Yes |
| Environmental | |
|---|---|
| Operating Temperature | -40°C to +80°C (-40°F to +176°F) |
| Storage Temperature | -40°C~85°C (-40°F~185°F) |
| Ambient Relative Humidity | 5%~95%, 55° (Non-condensing) |
| Mechanical | |
|---|---|
| Housing | IP30 protection, SPCC metal housing |
| Dimensions(W x H x D) | 440.6 x 44 x 309 mm (1U Rack-mount) |
| Installation | 19’’ Rack-Mount (Kit included) |
| Weight | 4,000g |
| Reset Button | Yes |
| Certification | Standard |
|---|---|
| Safety | EN61010-1, EN 61010-2-201 |
| EMC | FCC Part 15, Subpart B, Class A, EN 55032, Class A, EN 61000-6-2, EN 61000-3-2, EN 61000-3-3, EN 55024, EN 61000-6-4, IEC 61850-3 / IEEE 1613 |
| RoHS II | Yes |
| REACH | Yes |
| Standard | Item | Test | Value | Level |
|---|---|---|---|---|
| IEC 61000-4-2 | ESD | Contact Discharge | ±8kV | 4 |
| IEC 61000-4-2 | ESD | Air Discharge | ±15kV | 4 |
| IEC 61000-4-3 | RS | Radiated (enclosure) | 20 V/m | 3 |
| IEC 61000-4-4 | EFT | AC Power Port | ±4.0kV | 4 |
| IEC 61000-4-4 | EFT | DC Power Port | ±4.0kV | 4 |
| IEC 61000-4-4 | EFT | Signal Port | ±4.0KV | 4 |
| IEC 61000-4-5 | Surge | AC Power Port (L-2-L) | Line-to Line±2.0KV | 4 |
| IEC 61000-4-5 | Surge | AC Power Port (L-2-E) | Line-to Earth±4.0KV | 4 |
| IEC 61000-4-5 | Surge | DC Power Port (L-2-L) | Line-to Line±1.0KV | 3 |
| IEC 61000-4-5 | Surge | DC Power Port (L-2-E) | Line-to Earth±2.0KV | 3 |
| IEC 61000-4-5 | Surge | Signal Port (L-2-E) | Line-to Earth±4.0KV | 4 |
| IEC 61000-4-6 | CS | AC Power Port | 10 V rms | 3 |
| IEC 61000-4-6 | CS | DC Power Port | 10 V rms | 3 |
| IEC 61000-4-6 | CS | Signal Port | 10 V rms | 3 |
| IEC 61000-4-8 | PFMF | Enclosure | 100 A/m 1000 A/m (1sec.) | 5 6 |
| IEC 61000-4-11 | DIP | AC Power Port | 30% reduction (Voltage Dips), 1 period 60% reduction (Voltage Dips), 50 period 100%, reduction (Voltage interruptions), 5 period 100% reduction (Voltage interruptions), 50 period | - |
| Certification | Standard |
|---|---|
| Shock | MIL-STD-810F Method 516.5 |
| Drop (Freefall) | MIL-STD-810F Method 516.5 |
| Vibration | MIL-STD-810F Method 514.5 C1 & C2 |
| RoHS | Yes |
| MTBF | SE5908A-6SFP-Sis-HV: 13.01 years; SE5916A-6SFP-Sis: 12.13 years |
| Warranty | 5 years |
| MODEL NAME | PART NUMBER | DESCRIPTION | ETHERNET PORTS | SERIAL PORTS |
|---|---|---|---|---|
| SE5908A | Contact Headquarter | Ind. 8 Port Emb. Computer,10/100BASE-T(X) RJ45, DB9 | 2 (RJ45) | 1 (DB9) |
| SE5908A-6SFP | Contact Headquarter | Ind. 8 Port Emb. Computer, 100BASE-FX SFP slot, DB9 | 2 (RJ45) | 1 (TB5) |
| SE5908A-6SFP-HV | Contact Headquarter | Ind. 8 Port Emb. Computer, 100BASE-FX SFP slot, DB9 | 2 (RJ45) | 1 (DB9) |
| SE5908A-6SFP-Sis | Contact Headquarter | Ind. 8 Port Emb. Computer, 100BASE-FX SFP,Isolated | 2 (RJ45) | 1 (TB5) |
| SE5908A-6SFP-Sis-HV | Contact Headquarter | Ind. 8 Port Emb. Computer, 100BASE-FX SFP,Isolated | ||
| SE5908A-6SFP-TB | Contact Headquarter | Ind. 8 Port Emb. Computer, 100BASE-FX SFP slot, TB5 | ||
| SE5908A-6SFP-TB-HV | Contact Headquarter | Ind. 8 Port Emb. Computer, 100BASE-FX SFP slot, TB5 | ||
| SE5908A-HV | Contact Headquarter | Ind. 8 Port Emb. Computer,10/100BASE-T(X) RJ45, DB9 | ||
| SE5908A-Sis | Contact Headquarter | Ind. 8 Port Emb. Comp.,10/100BASET(X) RJ45, Isolated | ||
| SE5908A-Sis-HV | Contact Headquarter | Ind. 8 Port Emb. Comp.,10/100BASET(X) RJ45, Isolated | ||
| SE5908A-TB | Contact Headquarter | Ind. 8 Port Emb. Computer,10/100BASE-T(X) RJ45, TB5 | ||
| SE5908A-TB-HV | Contact Headquarter | Ind. 8 Port Emb. Computer,10/100BASE-T(X) RJ45, TB5 | ||
| Please note the following suffixes to be added to he chosen model name: SDK version suffix: (SDK) | 2 | 1 |
| MODEL NAME | PART NUMBER | DESCRIPTION |
|---|---|---|
| SDR-75-24 | 50500752240001G | 75W/3.2A DIN-Rail 24VDC power supply with 88~264VAC / 124~370VDC input |
| CBL-RJ45(8P)-DB9(F)-90-C | 50891971G | 8-pin RJ45-DB9 debug cable, 90cm |
| ADP-DB9(F)-TB5 | 59906231G | Female DB9 to Female 3.81 TB5 Converter |
| GDC-120 | 59906861G | 120mm copper woven grounding cable |
| WMK-450-Black | 70100000000052G | Aluminum wall mount kit |
| LM28-C3S-TI-N | 50708031G | SFP Transceiver, 1250Mbps, 850nmVCSEL, Multi-mode, 550m, 3.3V, -20~85°C |
| LM38-A3S-TI-N | 50708051G | SFP Transceiver, 155Mbps, 1310nmLED, Multi-mode, 2km, 3.3V, -40~85C |
| LS38-A3S-TI-N | 50709431G | SFP Transceiver, 155Mbps, 1310nmFP, Single-mode, 30km, 3.3V, -40~85C |
| LS38-C3L-TI-N | 50709441G | SFP Transceiver, 1250Mbps, 1310nmDFB, Single-mode, 30km, 3.3V, -40~85°C |
| AXFD-1314-0523 | 522AXFD1314001G | SFP Transceiver; 155Mbps, Multi-mode; 1310nm; 2km; -40°C to +85°C, DDMI |
| AXFD-1314-0553 | 522AXFD1314011G | SFP Transceiver; 155Mbps, Single-mode; 1310nm; 30km; 40°C to +85°C, DDMI |
| VERSION | NAME | TIME | SIZE | DOWNLOAD |
|---|---|---|---|---|
| v1.1 | Datasheet EN | 2024-03-21 | 506.15 KB | |
| 4 older versions | ||||
| VERSION | NAME | TIME | SIZE | DOWNLOAD |
|---|---|---|---|---|
| v1.4 | SE5908A Hardware Installation Guide | 2024-01-30 | 3.37 MB | |
| v1.3 | SE5916A/MB5916A/PG5916A Hardware Installation Guide | 2017-01-23 | 4.39 MB |
| VERSION | NAME | TIME | SIZE | DOWNLOAD |
|---|---|---|---|---|
| v0.1 | AWS getting started guide | 2021-08-19 | 907.53 KB | |
| v0.5 | SE59XX SDK User Manual | 2021-04-13 | 2.55 MB | |
| 2 older versions | ||||
| v1.4 | SE59XX Node-RED User Manual | 2019-04-22 | 5.72 MB | |
| 1 older version | ||||
| VERSION | NAME | TIME | SIZE | DOWNLOAD |
|---|---|---|---|---|
| v2.01 | SE5908A Firmware | 2021-03-22 | 10.28 MB |
| VERSION | NAME | TIME | SIZE | DOWNLOAD |
|---|---|---|---|---|
| v1.0 | Linux Driver_x64 | 2021-03-29 | 210.16 KB |