| Network Interface | |
|---|---|
| Speed | IEEE 802.3 10BaseT IEEE 802.3u 100BaseT(X) IEEE 802.3u for 100Base-X (SFP version only) IEEE 802.3z for 1000Base-X (SFP version only) |
| PoE standard supported | IEEE 802.3 af (-PoE version only) |
| LAN Mode | Dual Subnets or Network Redundancy |
| Connector ports | 2x 10/100BASE-T(X) RJ-45 or 2x 100/1000 Base-X SFP Slots (SFP version) |
| Serial Interface | |
|---|---|
| Connector | 1x2 5 pin 3.81mm Terminal Block, or D-sub9 connector |
| Ports | 4 |
| Mode | RS-232/422/485, software selectable |
| Baud Rate | 1,200~921,600 bps |
| Parity | None, Odd, Even |
| Data Bits | 7,8 |
| Stop Bits | 1,2 |
| Isolation | 2 KV |
| Other Interfaces | |
|---|---|
| USB Ports | 1 |
| Speed | USB 2.0 |
| Connector | USB A Type |
| Software | |
|---|---|
| Protocols | IPv4, ARP, ICMP, TCP, UDP, DHCP Client, DNS Client, Telnet, HTTP, HTTPS, SMTP/TLS, SNMP v1/v2c/v3, Syslog, 802.1D-2004 RSTP, OpenVPN or IPsec VPN (peer-to-peer or peer-to-side), with a maximum VPN throughput of 37.9Mbps(*), and PPTP |
| Configuration | Atop Management Utility, Web UI, Telnet, Serial Console, ATOP eNode Designer |
| Protocol setting | eNode designer |
| Supported Protocols | Modbus TCP/RTU/ASCII, DNP3.0 over serial and TCP/IP, IEC61850, IEC60870-5-101, IEC60870-5-103, IEC60870-5-104 |
| Protocol specifications | Refer to datasheet |
| Power | Value |
|---|---|
| Input Voltage | Dual 12 - 48VDC (non-PoE Models); or through Ethernet Cable (PoE versions) |
| Input Current (@ 12VDC) | 0.65 A @ 12 VDC |
| Power Consumption | Approximately 8 W (Max) |
| Connector | 7-Pin 5.08mm Lockable Terminal Block |
| Power Redundancy | Yes |
| Reverse Polarity Protection | Yes |
| Relay Output | 1A @ 30 VDC (normal open) |
| Physical Characteristics | Value |
|---|---|
| Housing | IP30 SPCC housing |
| Dimension (W x H x D) | 55 x 145 x 113 mm |
| Weight | 1,000g |
| Installation | DIN-Rail , Wall mount (optional kit) |
| Reset Button | Yes |
| Environmental Limits | |
|---|---|
| Operating Temperature | -40°C~85°C (-40°F~185°F) |
| Storage Temperature | -40°C~85°C (-40°F~185°F) |
| Ambient Relative Humidity | 5%~95%, 55°C (Non-condensing) |
| Certification | Standard |
|---|---|
| Safety | IEC/EN 61010-1, UL61010-1, IEC/EN 61010-2-201, UL61010-2-201, EN62368-1 |
| EMC | FCC Part 15, Subpart B, Class A EN 55032, EN 61000-3-2, EN 61000-3-3, EN 55024, EN 61000-6-2, EN 61000-6-4 |
| Standard | Item | Test | Value | Level |
|---|---|---|---|---|
| IEC 61000-4-2 | ESD | Contact Discharge | ±6kV | 3 |
| IEC 61000-4-2 | ESD | Air Discharge | ±8kV | 3 |
| IEC 61000-4-3 | RS | 80-1000MHz | 10 V/m | 3 |
| IEC 61000-4-3 | RS | 1.4-2.0GHz | 3 V/m | 2 |
| IEC 61000-4-3 | RS | 2.0-2.7GHz | 1 V/m | 1 |
| IEC 61000-4-4 | EFT | DC Power Port | ±2.0kV | 3 |
| IEC 61000-4-4 | EFT | Signal Port | ±2.0KV | 4 |
| IEC 61000-4-5 | Surge | DC Power Port | Line-to Line±1.0KV | 3 |
| IEC 61000-4-5 | Surge | DC Power Port | Line-to Earth±1.0KV | 2 |
| IEC 61000-4-5 | Surge | Signal Port | Line-to Earth±2.0K | 3 |
| IEC 61000-4-6 | CS | 0.15-80MHz | 10 Vrms | 3 |
| IEC 61000-4-8 | PFMF | Enclosure | 30 A/m | 4 |
| Certification | Standard |
|---|---|
| Shock | MIL-STD-810G Method 516.7 |
| Drop (Freefall) | MIL-STD-810G Method 516.7 |
| Vibration | MIL-STD-810G Method 514.7 |
| RoHS | Yes |
| MTBF | 14.56 Years (according to MIL-HDBK-217F) |
| Warranty | 5 Years |
| HARDWARE | |
|---|---|
| PG5904D-4P-DB | Industrial 4-Port Protocol Gateway, 10/100BASE-T(X), DB9 |
| PG5904D-4P-TB | Industrial 4-Port Protocol Gateway, 10/100BASE-T(X), TB5 |
| PG5904D-4P-Sis | Industrial 4-Port Protocol Gateway, 10/100BASE-T(X), Isolation |
| PG5904D-4P-PoE-DB | Industrial 4-Port Protocol Gateway, 10/100BASE-T(X) with PoE, DB9 |
| PG5904D-4P-PoE-TB | Industrial 4-Port Protocol Gateway, 10/100BASE-T(X) with PoE, TB5 |
| PG5904D-4P-PoE-Sis | Industrial 4-Port Protocol Gateway, 10/100BASE-T(X) With PoE, Isolation |
| PG5904D-4P-G-DB-SFP | Industrial 4-Port Protocol Gateway, 100/1000BASE-X with SFP Slot, DB9 |
| PG5904D-4P-G-TB-SFP | Industrial 4-Port Protocol Gateway, 100/1000BASE-X with SFP Slot, TB5 |
| PG5904D-4P-G-Sis-SFP | Industrial 4-Port Protocol Gateway, 100/1000BASE-X with SFP Slot, Isolation |
| Protocols | |
|---|---|
| 01SS-03SM | IEC 60870-5-101 Serial Slave to IEC 60870-5-103 Serial Master |
| 01SS-04EC | IEC 60870-5-101 Serial Slave to IEC 60870-5-104 Ethernet Client |
| 01SS-50EC | IEC 60870-5-101 Serial Slave to IEC 61850 Client |
| 01SS-DNEC | IEC 60870-5-101 Serial Slave to DNP3 Ethernet Client |
| 01SS-DNSM | IEC 60870-5-101 Serial Slave to DNP3 Serial Master |
| 01SS-MBEC | IEC 60870-5-101 Serial Slave to Modbus Ethernet Client |
| 01SS-MBSM | IEC 60870-5-101 Serial Slave to Modbus Serial Master |
| 04ES-01SM | IEC 60870-5-104 Ethernet Server to IEC 60870-5-101 Serial Master |
| 04ES-03SM | IEC 60870-5-104 Ethernet Server to IEC 60870-5-103 Serial Master |
| 04ES-50EC | IEC 60870-5-104 Ethernet Server to IEC 61850 Ethernet Client |
| 04ES-DNEC | IEC 60870-5-104 Ethernet Server to DNP3 Ethernet Client |
| 04ES-DNSM | IEC 60870-5-104 Ethernet Server to DNP3 Serial Master |
| 04ES-MBEC | IEC 60870-5-104 Ethernet Server to Modbus Ethernet Client |
| 04ES-MBSM | IEC 60870-5-104 Ethernet Server to Modbus Serial Master |
| 50ES-01SM | IEC 61850 Ethernet Server to IEC 60870-5-101 Serial Master |
| 50ES-03SM | IEC 61850 Ethernet Server to IEC 60870-5-103 Serial Master |
| 50ES-04EC | IEC 61850 Ethernet Server to IEC 60870-5-104 Ethernet Client |
| 50ES-DNEC | IEC 61850 Ethernet Server to DNP3 Ethernet Client |
| 50ES-DNSM | IEC 61850 Ethernet Server to DNP3 Serial Master |
| 50ES-MBEC | IEC 61850 Ethernet Server to Modbus Ethernet Client |
| 50ES-MBSM | IEC 61850 Ethernet Server to Modbus Serial Master |
| DNES-01SM | DNP3 Ethernet Server to IEC 60870-5-101 Serial Master |
| DNES-03SM | DNP3 Ethernet Server to IEC 60870-5-103 Serial Master |
| DNES-04EC | DNP3 Ethernet Server to IEC 60870-5-104 Ethernet Client |
| DNES-50EC | DNP3 Ethernet Server to IEC 61850 Ethernet Client |
| DNES-DNSM | DNP3 Ethernet Server to DNP3 Serial Master |
| DNES-MBEC | DNP3 Ethernet Server to Modbus Ethernet Client |
| DNES-MBSM | DNP3 Ethernet Server to Modbus Serial Master |
| DNSS-01SM | DNP3 Serial Slave to IEC 60870-5-101 Serial Master |
| DNSS-03SM | DNP3 Serial Slave to IEC 60870-5-103 Serial Master |
| DNSS-04EC | DNP3 Serial Slave to IEC 60870-5-104 Ethernet Client |
| DNSS-50EC | DNP3 Serial Slave to IEC 61850 Ethernet Client |
| DNSS-DNEC | DNP3 Serial Slave to DNP3 Ethernet Client |
| DNSS-MBEC | DNP3 Serial Slave to Modbus Ethernet Client |
| DNSS-MBSM | DNP3 Serial Slave to Modbus Serial Master |
| MBES-01SM | Modbus Ethernet Server to IEC 60870-5-101 Serial Master |
| MBES-03SM | Modbus Ethernet Server to IEC 60870-5-103 Serial Master |
| MBES-04EC | Modbus Ethernet Server to IEC 60870-5-104 Ethernet Client |
| MBES-50EC | Modbus Ethernet Server to IEC 61850 Ethernet Client |
| MBES-DNEC | Modbus Ethernet Server to DNP3 Ethernet Client |
| MBES-DNSM | Modbus Ethernet Server to DNP3 Serial Master |
| MBSS-01SM | Modbus Serial Slave to IEC 60870-5-101 Serial Master |
| MBSS-03SM | Modbus Serial Slave to IEC 60870-5-103 Serial Master |
| MBSS-04EC | Modbus Serial Slave to IEC 60870-5-104 Ethernet Client |
| MBSS-50EC | Modbus Serial Slave to IEC 61850 Client |
| MBSS-DNEC | Modbus Serial Slave to DNP3 Ethernet Client |
| MBSS-DNSM | Modbus Serial Slave to DNP3 Serial MasterMBSS-MBEC |
| FL | Allows a model to run single or multiple protocol(s) in both front-end to SCADA and back-end to IED sides |
| Optional Accessories | ||
|---|---|---|
| SDR-75-24 | 50500752240001G | 75W/3.2A DIN-Rail 24VDC power supply with 88~264VAC / 124~370VDC input |
| CBL-RJ45(8P)-DB9(F)-90-C | 50891971G | 8-pin RJ45-DB9 debug cable, 90cm |
| ADP-DB9(F)-TB5 | 59906231G | Female DB9 to Female 3.81 TB5 Converter |
| GDC-120 | 59906861G | 120mm copper woven grounding cable |
| WMK-450-Black | 70100000000052G | Aluminum wall mount kit |
| LM28-C3S-TI-N | 50708031G | SFP Transceiver, 1250Mbps, 850nmVCSEL, Multi-mode, 550m, 3.3V, -20~85°C |
| LM38-C3S-TI-N | 50709411G | SFP Transceiver, 1250Mbps, 1310nmFP, Multi-mode, 2km, 3.3V, -40~85°C |
| LS38-C3S-TI-N | 50709391G | SFP Transceiver, 1250Mbps, 1310nmFP, Single-mode, 10km, 3.3V, -40~85°C |
| LS38-C3L-TI-N | 50709441G | SFP Transceiver, 1250Mbps, 1310nmDFB, Single-mode, 30km, 3.3V, -40~85°C |
| VERSION | NAME | TIME | SIZE | DOWNLOAD |
|---|---|---|---|---|
| v2.3 | Datasheet EN | 2025-08-13 | 217.75 KB |
| VERSION | NAME | TIME | SIZE | DOWNLOAD |
|---|---|---|---|---|
| v1.1 | SE5904D/MB5904D/PG5904D Hardware Installation Guide | 2016-03-23 | 3.81 MB |
| VERSION | NAME | TIME | SIZE | DOWNLOAD |
|---|---|---|---|---|
| v2.0 | eNode designer - Caution: PG59xx v0.66 and the older version should use eNode v1.31 | 2024-12-30 | 7.18 MB | |
| v1.31 | eNode designer - Support PG59xx v0.66 and the older version | 2024-12-30 | 7.18 MB | |
| v1.28 | eNode designer - Caution: v1.27 and newer only support Protocol Gateway version 0.58 or newer | 2022-07-06 | 6.49 MB | |
| 1 older version | ||||
| v1.0 | Tcpdump for diagnosis | 2021-03-29 | 1.22 MB | |
| v5.60 | Management Utility for Windows | 2021-01-18 | 23.65 MB | |
| 1 older version | ||||
| v1.26 | eNode designer | 2020-05-11 | 6.45 MB | |
| VERSION | NAME | TIME | SIZE | DOWNLOAD |
|---|---|---|---|---|
| v1.0 | STP file PG-SE-MB5904D | 2022-07-07 | 1.87 MB |