| Network Interface | |
|---|---|
| Compliance | IEEE 802.3 10BaseT IEEE 802.3u 100BaseT(X) |
| LAN Mode | Dual Subnets or RSTP LAN Redundancy |
| Ethernet Port | 2x RJ-45 |
| Serial Interface | |
|---|---|
| Connector | RJ-45 |
| Ports | 16 |
| Mode | RS-232/422/485, software selectable |
| Baud Rate | 1,200 ~ 921,600 bps |
| Parity | None, Odd, Even |
| Data Bits | 5, 6, 7, 8 |
| Stop Bits | 1, 2 |
| Flow Control | None, Xon/Xoff, RTS/CTS |
| Isolation | 2.5 kV (Sis versions only) |
| Software | |
|---|---|
| Protocols | IPv4, ARP, ICMP, TCP, UDP, DHCP Client, DNS Client, Telnet, HTTP, HTTPS, SMTP/TLS, SNMP v1/v2c/v3, Syslog, RSTP, OpenVPN or IPsec VPN (peer-to-peer or peer-to-side), with a maximum VPN throughput of 37.9Mbps(*), and PPTP |
| Configuration | Atop Management Utility, Web UI, Telnet, Serial Console, ATOP eNode Designer |
| Protocol setting | eNode designer |
| Supported Protocols | Modbus TCP/RTU/ASCII, DNP3.0 over serial and TCP/IP, IEC61850, IEC60870-5-101, IEC60870-5-103, IEC60870-5-104 |
| Protocol specifications | Refer to datasheet |
| Power | Value |
|---|---|
| Rated Supply Voltage | DC version: 24-48VDC; US-EU version: 100-240 VAC (EU or US Plug) |
| Input Voltage Range | DC version: 24-48VDC; US-EU version: 90-264 VAC (EU or US Plug) |
| Input Current | DC version: 0.54 A @24VDC; US-EU version: 0.21A@100VAC |
| Power Consumption | 0.54A @ 24 VDC 0.21A @ 100 VAC |
| Connector | IEC 60320-1 C14 AC Power Inlet (AC models) 5.08mm 3-pin Lockable Terminal Block (DC models) |
| Power Redundancy | No |
| Reverse Polarity Protection | Yes (DC version only) |
| Relay Output | Yes (1) |
| Physical Characteristics | Value |
|---|---|
| Housing | IP30, SPCC housing |
| Dimension (W x H x D) | 436 mm x 43.5 mm x 200 mm |
| Weight | 3,000g (8-port version); 3,200 g (16-port version) |
| Installation | 19’’ Rack-Mount (Kit included) |
| Reset Button | Yes |
| Environmental Limits | |
|---|---|
| Operating Temperature | -20°C~70°C (-4°F~158°F) |
| Storage Temperature | -40°C~85°C (-40°F~185°F) |
| Ambient Relative Humidity | 5%~95%, 55°C (Non-condensing) |
| Certification | Standard |
|---|---|
| Safety | EN60950-1:2006; EN62368-1 |
| EMC | FCC Part 15, Subpart B, Class A EN 55032, Class A EN 61000-3-2 EN 61000-3-3 EN 55024 |
| RoHS 2 | Yes |
| REACH | Yes |
| Standard | Item | Test | Value | Level |
|---|---|---|---|---|
| IEC 61000-4-2 | ESD | Contact Discharge | ±8kV (For AC Version) | 4 |
| IEC 61000-4-2 | ESD | Air Discharge | ±15kV (For AC Version) | 4 |
| IEC 61000-4-2 | ESD | Contact Discharge | ±6kV (For DC Version) | 3 |
| IEC 61000-4-2 | ESD | Air Discharge | ±8kV (For DC Version) | 3 |
| IEC 61000-4-3 | RS | Radiated (enclosure) | 10 V/m | 3 |
| IEC 61000-4-4 | EFT | AC Power Port | ±4.0kV | 4 |
| IEC 61000-4-4 | EFT | DC Power Port | ±4.0kV | 4 |
| IEC 61000-4-4 | EFT | Signal Port | ±2.0KV | 3 |
| IEC 61000-4-5 | Surge | AC Power Port (L-2-L) | ±2.0KV | 4 |
| IEC 61000-4-5 | Surge | AC Power Port (L-2-E) | ±4.0KV | 4 |
| IEC 61000-4-5 | Surge | DC Power Port (L-2-L) | ±1.0KV | 3 |
| IEC 61000-4-5 | Surge | DC Power Port (L-2-E) | ±2.0KV | 3 |
| IEC 61000-4-5 | Surge | Signal Port (L-2-L) | ±2.0KV | 4 |
| IEC 61000-4-6 | CS | AC Power Port | 10 V rms | 3 |
| IEC 61000-4-6 | CS | DC Power Port | 10 V rms | 3 |
| IEC 61000-4-6 | CS | Signal Port | 10 V rms | 3 |
| IEC 61000-4-8 | PFMF | Enclosure | 1 A/m | 3 |
| IEC 61000-4-11 | DIP | AC Power Port | 30% Reduction (Voltage Dips), 25/30 Cycle >95% Reduction (Voltage Dips), 0.5 period 100% Reduction (Voltage Inter- ruption): 250/300 Cycle | - |
| Certification | Standard |
|---|---|
| Shock | IEC 60068-2-27 |
| Drop | ISTA Test Procedure 2A |
| Vibration | IEC 60068-2-64 |
| Warranty | 5 Years |
| MTBF | PG5908-SiS-DC: 19.00 years; PG5908-SiS-US/EU: 19.03 years PG5916-SiS-DC: 13.38 years; PG5916-SiS-US/EU: 13.38 years |
| HARDWARE | ETHERNET PORTS | SERIAL PORTS | |
|---|---|---|---|
| PG5916-DC | Ind. 16-Port Protocol Gateway,RS-232/422/485 Software Selectable, DC TB3 | 2 (RJ45) | 16 (RJ45) |
| PG5916-EU | Ind. 16 Port Protocol Gateway, RS-232/422/485 Software Selectable, AC Inlet, EU Plug | 2 (RJ45) | 16 (RJ45) |
| PG5916-US | Ind. 16 Port Protocol Gateway, RS-232/422/485 Software Selectable, AC Inlet, US Plug | 2 (RJ45) | 16 (RJ45) |
| PG5916-SiS-DC | Ind. 16 Port Protocol Gateway, RS-422/485 Software Selectable, 2.5kV isolation, DC TB3 | 2 (RJ45) | 16 (RJ45) |
| PG5916-SiS-EU | Ind. 16 Port Protocol Gateway, RS-422/485 Software Selectable, 2.5kV isolation, AC Inlet, EU Plug | 2 (RJ45) | 16 (RJ45) |
| PG5916-SiS-US | Ind. 16 Port Protocol Gateway, RS-422/485 Software Selectable, 2.5kV isolation, AC Inlet, US Plug | 2 (RJ45) | 16 (RJ45) |
| Protocols | |
|---|---|
| 01SS-03SM | IEC 60870-5-101 Serial Slave to IEC 60870-5-103 Serial Master |
| 01SS-04EC | IEC 60870-5-101 Serial Slave to IEC 60870-5-104 Ethernet Client |
| 01SS-50EC | IEC 60870-5-101 Serial Slave to IEC 61850 Client |
| 01SS-DNEC | IEC 60870-5-101 Serial Slave to DNP3 Ethernet Client |
| 01SS-DNSM | IEC 60870-5-101 Serial Slave to DNP3 Serial Master |
| 01SS-MBEC | IEC 60870-5-101 Serial Slave to Modbus Ethernet Client |
| 01SS-MBSM | IEC 60870-5-101 Serial Slave to Modbus Serial Master |
| 04ES-01SM | IEC 60870-5-104 Ethernet Server to IEC 60870-5-101 Serial Master |
| 04ES-03SM | IEC 60870-5-104 Ethernet Server to IEC 60870-5-103 Serial Master |
| 04ES-50EC | IEC 60870-5-104 Ethernet Server to IEC 61850 Ethernet Client |
| 04ES-DNEC | IEC 60870-5-104 Ethernet Server to DNP3 Ethernet Client |
| 04ES-DNSM | IEC 60870-5-104 Ethernet Server to DNP3 Serial Master |
| 04ES-MBEC | IEC 60870-5-104 Ethernet Server to Modbus Ethernet Client |
| 04ES-MBSM | IEC 60870-5-104 Ethernet Server to Modbus Serial Master |
| 50ES-01SM | IEC 61850 Ethernet Server to IEC 60870-5-101 Serial Master |
| 50ES-03SM | IEC 61850 Ethernet Server to IEC 60870-5-103 Serial Master |
| 50ES-04EC | IEC 61850 Ethernet Server to IEC 60870-5-104 Ethernet Client |
| 50ES-DNEC | IEC 61850 Ethernet Server to DNP3 Ethernet Client |
| 50ES-DNSM | IEC 61850 Ethernet Server to DNP3 Serial Master |
| 50ES-MBEC | IEC 61850 Ethernet Server to Modbus Ethernet Client |
| 50ES-MBSM | IEC 61850 Ethernet Server to Modbus Serial Master |
| DNES-01SM | DNP3 Ethernet Server to IEC 60870-5-101 Serial Master |
| DNES-03SM | DNP3 Ethernet Server to IEC 60870-5-103 Serial Master |
| DNES-04EC | DNP3 Ethernet Server to IEC 60870-5-104 Ethernet Client |
| DNES-50EC | DNP3 Ethernet Server to IEC 61850 Ethernet Client |
| DNES-DNSM | DNP3 Ethernet Server to DNP3 Serial Master |
| DNES-MBEC | DNP3 Ethernet Server to Modbus Ethernet Client |
| DNES-MBSM | DNP3 Ethernet Server to Modbus Serial Master |
| DNSS-01SM | DNP3 Serial Slave to IEC 60870-5-101 Serial Master |
| DNSS-03SM | DNP3 Serial Slave to IEC 60870-5-103 Serial Master |
| DNSS-04EC | DNP3 Serial Slave to IEC 60870-5-104 Ethernet Client |
| DNSS-50EC | DNP3 Serial Slave to IEC 61850 Ethernet Client |
| DNSS-DNEC | DNP3 Serial Slave to DNP3 Ethernet Client |
| DNSS-MBEC | DNP3 Serial Slave to Modbus Ethernet Client |
| DNSS-MBSM | DNP3 Serial Slave to Modbus Serial Master |
| MBES-01SM | Modbus Ethernet Server to IEC 60870-5-101 Serial Master |
| MBES-03SM | Modbus Ethernet Server to IEC 60870-5-103 Serial Master |
| MBES-04EC | Modbus Ethernet Server to IEC 60870-5-104 Ethernet Client |
| MBES-50EC | Modbus Ethernet Server to IEC 61850 Ethernet Client |
| MBES-DNEC | Modbus Ethernet Server to DNP3 Ethernet Client |
| MBES-DNSM | Modbus Ethernet Server to DNP3 Serial Master |
| MBSS-01SM | Modbus Serial Slave to IEC 60870-5-101 Serial Master |
| MBSS-03SM | Modbus Serial Slave to IEC 60870-5-103 Serial Master |
| MBSS-04EC | Modbus Serial Slave to IEC 60870-5-104 Ethernet Client |
| MBSS-50EC | Modbus Serial Slave to IEC 61850 Client |
| MBSS-DNEC | Modbus Serial Slave to DNP3 Ethernet Client |
| MBSS-DNSM | Modbus Serial Slave to DNP3 Serial MasterMBSS-MBEC |
| FL | Allows a model to run single or multiple protocol(s) in both front-end to SCADA and back-end to IED sides |
| OPTIONAL ACCESSORIES | ||
|---|---|---|
| SDR-75-24 | 50500752240001G | 75W/3.2A DIN-Rail 24VDC power supply with 88~264VAC / 124~370VDC input |
| Power Adapter AD17-24C (US-Y) | 50500151240002G | Y-Type power adaptor,100-240VAC input, 0.6A @ 24VDC output, US plug |
| Power Adapter AD17-24D (EU-Y) | 50500151240012G | Y-Type power adaptor,100-240VAC input, 0.6A @ 24VDC output, EU plug |
| GDC-120 | 59906861G | 120mm copper woven grounding cable |
| CBL-RJ45(8P)-DB9(M)-90 | 50891781G | RJ45 to DB9 Male Cable, 90cm |
| CBL-RJ45(8P)-DB9(M)-200 | 50891951G | RJ45 to DB9 Male Cable, 200cm |
| CBL-RJ45(8P)-DB9(F)-90 | 50891791G | RJ45 to DB9 Female Cable, 90cm |
| CBL-RJ45(8P)-DB9(F)-90-C | 50891971G | RJ45 to DB9 Female Cross Over Cable, 90cm |
| CBL-RJ45(8)-DB9(F)-200-C | 50891961G | RJ45 to DB9 Female Cross Over Cable, 200cm |
| RMK-718-Black | 70100000000040G | Rack Mount Mounting-Kit, Black |
| Power Cable (US) | 50801041G | 6 feet Power Cable, US |
| Power Cable (EU) | 50801051G | 6 feet Power Cable, EU |
| Fuse | 50709441G | Fuse |
| VERSION | NAME | TIME | SIZE | DOWNLOAD |
|---|---|---|---|---|
| v1.5 | Datasheet EN | 2025-08-13 | 218.67 KB | |
| 4 older versions | ||||
| VERSION | NAME | TIME | SIZE | DOWNLOAD |
|---|---|---|---|---|
| v2.0 | SE5908/MB5908/PG5908 Hardware Installation Guide | 2019-06-06 | 1.87 MB |
| VERSION | NAME | TIME | SIZE | DOWNLOAD |
|---|---|---|---|---|
| v2.0 | eNode designer - Caution: PG59xx v0.66 and the older version should use eNode v1.31 | 2024-12-30 | 7.18 MB | |
| v1.31 | eNode designer - Support PG59xx v0.66 and the older version | 2024-12-30 | 7.18 MB | |
| v1.28 | eNode designer - Caution: v1.27 and newer only support Protocol Gateway version 0.58 or newer | 2022-07-06 | 6.49 MB | |
| 1 older version | ||||
| v1.0 | Tcpdump for diagnosis | 2021-03-29 | 1.22 MB | |
| v5.60 | Management Utility for Windows | 2021-01-18 | 23.65 MB | |
| 1 older version | ||||
| v1.26 | eNode designer | 2020-05-11 | 6.45 MB | |
| VERSION | NAME | TIME | SIZE | DOWNLOAD |
|---|---|---|---|---|
| PG5908 Declarations of Conformity | 2023-03-10 | 278.35 KB | ||
| EN 62368-1(AC models) | 2022-11-08 | 3.91 MB | ||
| EN 62368-1(DC models) | 2022-11-08 | 3.38 MB |